117
Installing the metal
detector
paging aerials and loops, RF heaters, welders of all types and even airport radar. The only
cure is to re-orientate either detector head or the source of interference so that the aperture
is not looking directly at it.
Post-installation problems
Commissioning procedures are covered comprehensively in Service Bulletin MD20. Copies
are available on request.
Spurious triggering
Moving metal anywhere within the metal free area up to a distance of twice the smaller of the
aperture dimensions away from the head can be detected.
Examples of moving metal include:
• Operator rings or watches
• Belt contamination even by small particles of rust
• Metallic belt clips even if plastic coated
• Metallic guide rails particularly into the metal free area
• Loose infeed decking
• A conveyor bolted together rather than welded
• Metallic inks or labels
• Metallic frames to infeed or outfeed guards
• Low grade or reclaimed cardboard packing materials which often contain metallised paper
or foil
• Washers or swarf under the skid plate.
Other causes, include:
• Excessive vibration, particularly when run in reactive mode
• Eddy current loops
• Aperture pressure
• Electrical Interference and EMC considerations.