Connecting the air supply (pneumatically-operated reject valve only)
An air supply at a pressure of between 6.0 and 8.0 bar (90-116psi) is required when the
detector is fitted with an pneumatically-operated automatic reject valve. The minimum air
pressure should not fall below 75psi (5.2 bar) when the reject valve operates. The air supply
must be dry and lubricated.
• If a pneumatically-operated reject valve is fitted, connect the compressed air supply to the
input port of the 5-port valve via a 10mm O/D air tube. This valve is located at the rear
underside of the control box.
Checking the detector
• Check that all couplings are securely tightened and that the unit is not hanging from the
pipeline, or pressing upwards in such a way as to distort the assembly.
• Check that the four wheels are securely located on the floor and locked.
Powering up the detector
• Switch on the supply to the search head control unit.
• Switch on the air supply to the detector.
• Set up the unit as described in Setting up the metal detector, page 59.

Handtmann versions

This section describes how to install a Loma Handtmann metal detector. The detector is
mounted from the hinge block located on the filler outfeed adjacent to the filler product pipe.
Warnings
The following additional safety warnings apply to these procedures:
19. HANDLING A HINGE MOUNTED VERSION ON A PA30 FILLER
20. HANDLING A HINGE MOUNTED VERSION WITHOUT A STAND
21. HANDLING A HINGE MOUNTED VERSION ON A STAND
22. HANDLING WITH A WATER JACKET FITTED
23. OPERATING WHEN USED FOR HANDLINKING
24.DISCONNECTION OF POWER
For details see Safety warnings, page iii.