Aastra Web UI
Step
Action
3
In the "Time (24-hour)" field, select the time that you want the update to take place.
Valid values are 00:00 to 23:30 (in 30 minute increments).
Notes:
1. The resync time is based on the local time of the IP phone.
2. The value of 00:00 is 12:00 A.M.
3. When selecting a value for this parameter in the Aastra Web UI, the values are in 30-minute
increments only.
4
In the "Maximum Delay" field, specify the maximum time, in minutes, the phone waits past the
scheduled time before starting a checksync. The range is 0 to 1439. Default is 15.
5
In the "Days" field, specify the amount of days that the phone waits between checksync operations.
The range is 0 to 364. Default is 0.
Note: A value of 0 causes the phone to checksync every time the clock reads the proper time. A
value of 1 forces the phone to wait 24 hours prior to doing the first checksync.
6
Click
These changes are not dynamic.
You must restart your IP phone for the changes to take affect.
7
Click on Operation->Reset.
8
In the "Restart Phone" field click
The update performs automatically at the time you designated.
8-10
to save your settings.
to restart the IP phone and apply the update.