Aastra 9000i Series Administrator's Manual page 737

Ip sip phones
Hide thumbs Also See for 9000i Series:
Table of Contents

Advertisement

Parameter –
pc port passthru enabled
Description
Format
Default Value
Range
Example
A-12
IP phone UI
Options->Administrator Menu->
Network Settings->Ethernet Link
Aastra Web UI
Advanced Settings->Network->
Basic Network Settings
Configuration Files
aastra.cfg, <model>.cfg, <mac>.cfg
Enables or disables the PC port.
Note: PC Port parameters are not applicable to the 6730i IP Phone.
Integer
1 (enable)
0 (disable)
1 (enable)
pc port passthru enabled: 1
41-001343-01 Rev 02, Release 3.2.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

6700i series9000i6700i

Table of Contents