Parameter –
pc port passthru enabled
PC Port PassThru Enable/
Disable
(in Web UI)
Description
Format
Default Value
Range
Example
Parameter –
eap type
EAP Type
(in Web UI)
Description
Format
Default Value
Range
Example
A-118
IP phone UI
Options->Administrator Menu->
Network Settings->Ethernet Link
Aastra Web UI
Advanced Settings->Network->
Basic Network Settings
Configuration Files
aastra.cfg, <model>.cfg, <mac>.cfg
Enables or disables the PC port.
Integer
1 (enable)
0 (disable)
1 (enable)
pc port passthru enabled: 1
IP Phone UI:
Options->Administrator Menu->
Network Settings->Ethernet Link->
802.1x Settings->802.1x Mode
Aastra Web UI:
Advanced Settings->802.1x Support->General
Configuration Files aastra.cfg, <model>.cfg, <mac>.cfg
Specifies the type of authentication to use on the IP Phone.
Integer
0 (disable)
0 (disable)
1 (MD5)
2 (TLS)
eap type: 1