Programming a specific value for POWer : AMPLif ier : STATE sets
POWer:AMPLifier:STATE:AUTOto OFF.
POWer:AMPLifier:STATE:AUTO ONlOFFlOll
l
POWer:AMPLifier:STATE:AUTO?
l
Sets and queries the automatic selection of the doubler amplifier
state. Programming a specific value for POWer : AMPLif ier : STATE sets
POWer:AMPLifier:STATE:AUTO to OFF. *RSTvalue is ON.
POWer:ATTenuation <num>[DB] lMAXimumlMINimumlUPlDOWN
l
POWer : ATTenuat ion? [MAXimum 1 MINimum]
l
Sets and queries the output attenuation level. Note that when
setting the attenuator level to 10 dB the output power is
decreased by 10 dB. Programming a specified attenuation sets
POWer:ATTenuation:AUTO OFF.
POWer:ATTenuation:AUTO ONlOFFlllO
l
POWer:ATTenuation:AUTO?
l
Sets and queries the state of the RF attenuator coupling switch.
Programming a specified attenuation sets
POWer : ATTenuat ion : AUTO OFF.
ON - insures that the amplitude level of the ALC is kept within
optimal limits.
OFF - the attenuator setting is set to the value of POW :ATT and left
there. The "RST value is ON.
POWer:CENTer <num> [lvl suffix] lMAXimumlMINimumlUPlDOWN
l
l
POWer:CENTer? [MAXimumlMINimuml
Sets and queries the center power for power sweep. Default units
(and units for query response) are determined by the UNIT:POWer
command.
The coupling equations for power sweep are exactly analogous to
those for frequency sweep. Power sweep is allowed to be negative,
unlike frequency sweeps. See FREQ : CENT for a description. *RST
value is 0 dBm.
l
l
POWer [ : LEVel] ? [MAXimum 1 MINimum]
Sets and queries the output level. Default units and units
for the query response are determined by the UNIT:POWer
command. Maximum and minimum levels refer to the
leveling mode at the time the command is sent. For example,
from *RST;POWer:ALC:SOURceMMHead; POWer:LEVel MIN
After *RST, the value is 0 dBm.
POWer:MODE FIXedlSWEep
l
POWer:MODE?
l
Sets and queries the setting of the power sweep mode switch. If in
Operating and Programming Reference S-43