HP 8360
User's Handbook
This softkey lets you set the synthesizer's sweep time to a minimum
value for a chosen span and meet all specifications. The sweep time
is limited by a 300 MHz/ms sweep rate. An asterisk next to the key
label indicates this feature is active.
SCPI: SWEep:TIME:AUTO ONlOFFlllO
Analyzer: NONE
"Power Level and Sweep Time Operation" in Chapter 1.
SYSTEM
This hardkey reveals the system menu.
Alternate Regs
Dim
Display
Disp Status
Preset Mode Factory
Preset Mode User
Ref Osc Menu
Save User Preset
Security Menu
Software Rev
Causes the synthesizer to alternate
on successive sweeps between the
present instrument state and a second
instrument state stored in an internal
register.
Dims the synthesizer's display.
Displays the present status of the
synthesizer.
Reveals the HP-IB control menu.
Sets the preset state, as defined by the
manufacturer, to be recalled by the
Sets the preset state, as defined by the
user, to be recalled by (PRESET].
Reveals the frequency standard options
menu.
Stores the present instrument state in a
special preset storage register.
Reveals the menu that controls the
security features of the synthesizer.
Causes the synthesizer to display the
date code of its internal software.
Operating and Programming Reference S-77