This softkey (Option 002 only) lets you set a value for the internal
pulse generator's pulse period. The pulse is adjustable from
300 ns to 400 ms with '25 ns resolution. The factory preset default
is 2 ms pulse period. When this feature is active, its current value is
displayed in the active entry area.
Since period and rate are inversely related, if both are given values,
only the last one will be applied which will cause the first one to be
recalculated. Use the one that is convenient for your application. For
example, if you set the pulse period, do not change the pulse rate
(the synthesizer automatically adjusts the rate to match the period.)
SCPI:
PULS:INTernal:PERiod <num>[time suffix]lMAXimum(MINimum
Analyzer:
NONE
a so see "Pulse" and "Modulation".