Auto Track - HP 8360 User Handbook Manual

8360 series synthesized sweepers
Table of Contents

Advertisement

Programming Codes
See Also

Auto Track

Function Group
Menu Map 5,9
Description
Programming Codes
See Also
where X represents a numeric value. Unless a previous entry was
made, the display indicates the synthesizer maximum frequency.
SCPI:
NONE,see Fltaess Menu or List Menu
Analyzer:
NONE
Fltness Menu, List Menu
"Optimizing Synthesizer Performance" in Chapter 1.
POWER, USER CAL
This softkey optimizes the tracking of the synthesizer's output
filter to the oscillator. Use it to maximize RF power output. The
synthesizer displays: Peaking At: XXXXXMHz,where XXXXX
represents frequency values. Peaking begins at the low frequency
end and steps through to the high end of the frequency range. Auto
Track is complete when the display returns to its original state. On
synthesizers without a step attenuator provide a good source match
on the RF connector. Use a power sensor or a 10 dB attenuator. If
a good source match is not provided, the synthesizer can mistrack
because of excessive reflections at the output.
SCPI:
CALibration:TRACk
Analyzer:
SHRP
Tracking Menu
"Optimizing Synthesizer Performance" in Chapter 1.