Chapter 8
 
1) Open the right door.
F-8-388
2) Remove the reuse band [1], and disconnect the
connector [2].
3) Remove the 2 screws (M4x8; RS tightening), and
detach the right door.
F-8-389
Attaching the Right Door
1) Match the hinge [1] found at the bottom of the right
door against the lug.
2) Engage the hinge [2] found on the top of the right
door with the hook found on the side plate.
8-136
F-8-390
When tightening the 2 screws used to fix the hinge in
place, be sure to close the right door first.
8.8.23.4 Removing the Duplex
Feed Sensor
iR2270 / iR2870 / iR3570 / iR4570
1) Remove the 2 screws (w/ collar) [1], and detach the
transfer frame [2].
F-8-391
2) Disconnect the connector [1], and remove the
0007-6976