4) Remove the 3 screws [1], and detach the hopper
assembly [2].
F-7-89
When fitting the hopper assembly to the machine, be
sure that the connectors [1] are securely connected. If
the connectors [1] are not connected, the environment
heater will not be supplied with power, leading to
image faults.
F-7-90
7-40
7.12.4 Sub Hopper
7.12.4.1 Removing the Front
Cover Unit
iR2270 / iR2870 / iR3570 / iR4570
1) Open the front cover [1].
F-7-91
2) Remove the face cover rubber [1].
3) Remove the binding screw [2].
4) Remove the RS tightening screw [3].
5) Detach the front cover unit [4] by moving it in the
direction of the arrow.
F-7-92
7.12.4.2 Removing the Waste
Toner Case
iR2270 / iR2870 / iR3570 / iR4570
1) Remove the waste toner case [1].