It is taken for granted that the planning of the system, as well as installation, setting in
operation and maintenance works are executed by sufficiently instructed staff and that
these works are checked by responsible specialists. The indications on the name plate of
the machine must correspond to the technical sheet and the local connection conditions.
Conditions to be provided by the customer:
5.3.1 Requirements for the installation area
The machine is only frost-resistant in the state it is delivered or when provided with spe-
cial features (option: frost drainage). If the appliance is installed in an area where the
surrounding temperatures are below freezing point, the water freezing inside can dam-
IMPORTANT!
age the internal water components such as pump, solenoid valve, boiler, etc.
The machine must be set up so that there is a minimum distance of 300 mm between
the open hood and the ceiling.
IMPORTANT!
5.4
Work on the electrical part of the machine may only be undertaken by specialist person-
nel.
The customer must guarantee the following points relating to the connection:
Current applicable standards and requirements of local utility companies are to be ad-
hered to with regard to protective measures and connection of the potential compensa-
tion system.
IMPORTANT!
The products are intended for permanent connection to the on-site power supply and
have been tested for the market accordingly. Any other form of electrical connection is
to be established by a licensed electrician.
Do not protect by fuses any additional consumers together with the dishwashing ma-
chine.
The wiring diagram is behind the front panel, resp. front cladding of the appliance. The
enclosed wiring diagram must remain in the appliance.

Operating conditions

Frost free storage and installation area
Electrical connection in accordance with the technical sheet
Steam connection (option) as per dimension sheet
Fresh water connection in accordance with the technical sheet
Waste water connection in accordance with the technical sheet
Anti-slip floor coverings should be provided around the washing appliance.
Ensure that the storage and installation area is permanently frost free.
Only of automatic hood

Requirements for the electrical connection

The correct voltage and type of current must be available
Safeguard the power supply cable according to regulations and provide it with a
power disconnection device in the fixed electrical installation.
The machine must be connected to the potential compensation system!
If an unearthed neutral (N) is used with alternating current, the power disconnection
device must have 4-poles (with alternating current 2-poles).
For connection to three-phase current a 5-pole terminal strip (L1, L2, L3, N, PE)
must be used.
Electricity supply without neutral conductor (N): when connecting to three-phase
current, use a 4-pole clamping strip (L1, L2, L3, PE).
Conductor colors: live conductor L1 = black/1, L2 = brown/2, L3 = grey/3, neutral
conductor N = blue/4, protective earthing conductor PE = green-yellow.
All conductor fixing screws must be re-tightened before commissioning the appli-
ance.