Monitoring - CalAmp Fusion User Manual

High-performance multi-band lte router
Hide thumbs Also See for Fusion:
Table of Contents

Advertisement

Figure 58 Monitor & Control – Power Management
Shutdown Method
Disabled by default. Select "Power off" to enable power management. If disabled, the Fusion will continue to run
indefinitely even without the ignition on.
After Ignition Line Off
Select between the following time intervals: 1, 5, 30 or 60 minutes. The Debounce time serves to avoid false
detection and can be configured to values between 100 ms up to 3.2 seconds. This means that the Ignition must be
stable for at least this amount of time for it to be recognized as OFF.
When Voltage Drops Below
Enter desired voltage. Enter "0" to disable (and give precedence to time delay configured under "After ignition time
off").

3.11.6 MONITORING

The Fusion monitors some I/O and can report events when certain criteria are met. For example, a report can be
generated when the temperature goes above some threshold value. These events can then optionally be reported
through SNMP and NMEA independently. When NMEA is enabled, the user can define specific messages indicating
normal and abnormal conditions. SNMP reports, on the other hand, are based on a mechanism with traps and defined
in the SNMP protocol and the MIB structures.