Enabling/disabling
Multi-Feed Detector
8-2
The Multi-Feed Detector is controlled by two buttons located to the
left of the document output tray as you are facing the machine.
Calibrate
Enable
Calibrate (upper button) — allows you to calibrate the thickness threshold
limit.
Multi-Feed Detector Enable/Disable (lower button) — allows you to
enable or disable the Multi-Feed Detector.
NOTE: When the transport is running, you cannot change the Enable or
Calibrate state of the Multi-Feed Detector.
F72 Double Detection On/Off — allows you to use a function code to
enable and disable the system. The lights do not change.
When a multi-feed is detected, both buttons illuminate. Depending upon
the scanner firmware and how the unit is configured, one of the following
messages will be displayed:
E204 Double document - refeed
E107 Warning Double document - refeed
The Multi-Feed Detector Enable/Disable button indicates the state of the
accessory. If the lamp is ON, the accessory is enabled. While the transport
is stopped, press the lower button to enable or disable the accessory as
desired. The Multi-Feed Detector automatically enables after power-up or a
successful calibration as described in the next section.