4
Function Codes
Using function
codes
A-61139 March 2000
There are a variety of functions available which may be used to
temporarily change operating parameters, and to obtain system
and accessory status information.
These functions are listed in the Function Code Summary later in this
chapter. Following are the procedures for using function codes:
1. Press the F key.
2. Press the numeric keys which correspond to the desired function
code.
3. Press Enter.
If the function is used to enable or disable an operation (turn an option
on or off):
1. Press 1 to turn the option On, or 0 to turn the option Off.
2. Press Enter.
If the function requires numeric input:
1. Press the numeric key(s) required.
2. Press Enter.
If the function is used to increment or decrement a measurement or
setting:
Press the arrow keys to increment or decrement as follows:
Press the Up arrow to increment the measurement by
1 inch (25 mm) or one value, or
Press the Down arrow to decrement the measurement by
1 inch (25 mm) or one value, or
Press the Right arrow to increment the measurement by
1/8-inch (3 mm) or one value, or
Press the Left arrow to decrement the measurement by
1/8-inch (3 mm) or one value.
Press Enter.
To cancel a function (before pressing Enter) or clear the status display
after executing a function code:
Press C (Clear/Cancel).