Advertisement

Unsuccessful calibration
Preparing
documents for
scanning
A-61139 March 2000
If calibration is not successful, a message appears in the status display.
You may need to:
Verify you are using a clean, blank sheet of paper as a calibration
target.
Verify there is not a document already in the document path. (Refer
to the section entitled, "Clearing the document path" in Chapter 7.)
Clean the imaging guides. (Refer to the section entitled "Cleaning
the imaging guides" in Chapter 5.)
Calibrate the scanner again. If calibration fails again, change the
lamps. (Refer to the section entitled, "Replacing the exposure
lamps" in Chapter 5.)
If you have done all of the above and calibration still fails, contact your
service representative.
Before you begin processing documents, make certain that the
documents may be fed through the scanner easily.
Remove any staples, rubber bands, loose mending tape, or paper
clips from the documents to be processed.
Straighten wrinkled edges and tape any torn documents.
Trim ragged edges.