Enabling the
confirmation tone
Footswitch
Pressed actions
9-42
The Footswitch confirmation tone may be used to signal that action has
been taken as a result of the Footswitch being pressed or released.
If your machine is configured for no confirmation tones, then no
confirmation tones of any kind will be heard in any mode.
If your machine is configured to allow confirmation tones, then you
can disable (or enable) confirmation tones in any mode as desired.
If the machine confirmation tones and the Footswitch confirmation
tone are enabled during installation for the mode being used, you may
enable/disable the Footswitch confirmation tone during normal
operations by performing function code F75.
One Footswitch Pressed action can be defined per mode. When you
press (and/or release) the Footswitch, you can perform one of the
following actions. The action that is being performed is dependent upon
what is programmed during Mode Setup.
Footswitch Pressed
Definition
Next document Level 0
Next document Level 1
Next document Level 2
Next document Level 3
Increment Level
Function command
P-key
Action
The next document fed into the transport is
assigned Level 0.
The next document fed into the transport is
assigned Level 1.
The next document fed into the transport is
assigned Level 2.
The next document fed into the transport is
assigned Level 3.
The next document fed into the transport is
assigned the next higher document level (i.e.,
if the current document is assigned Level 2,
the next document is assigned Level 3).
The function code(s) for a Footswitch
pressed, programmed during Mode Setup, is
performed (i.e., if the Footswitch press
definition is f04,1, the Count Only mode is
activated when the Footswitch is pressed).
The function code(s) for a Footswitch
pressed, programmed during Mode Setup as
the P-key definition, is performed (i.e., if the
Footswitch pressed definition is P8, and P8 is
defined as f98f38, the transport stops and
signals end-of-job when the Footswitch is
pressed).