Kodak 9520 User Manual page 36

Document scanner
Hide thumbs Also See for 9520:
Table of Contents

Advertisement

Code
Function Code Name
F72
Double Detection
F73
Latched Scanning Flag
F74
Momentary Scanning Flag
F75
Footswitch Confirmation
Tone
F91
Select Linked Mode
F92
Fixed Field
F93
Action/Confirmation Tone
F94
Level 1
F95
Level 2
F96
Level 3
F97
Next Image Address
F98
Stop
F99
Run
4-10
Allows you to turn skew detection on or off which monitors
the amount of skew using predefined skew angle(s).
Enter 1 to turn on or 0 to turn off, then press Enter.
Allows you to set a flag in the image headers which alerts
the host system that this document, and those which
follow, are of special interest. The flag will remain
activated for every document until it is turned off. Enter 1
to turn on or 0 to turn off, then press Enter.
Allows you to set a flag in the image header which alerts
the host system that this document is of special interest.
This flag is set only for that one document. Enter 1 to turn
the momentary scanning flag on, then press Enter.
Allows you to turn the confirmation tone on or off which
informs you when the Footswitch is pressed and/or
released. Enter 1 to turn on or 0 to turn off, then press
Enter.
Allows you to switch from one application mode to
another, keeping the last image address. Enter the
number of the application mode you wish to select, then
press Enter.
Allows you to enter a new fixed field value containing
alphanumeric characters.
NOTE: If the fixed field width for the mode you are using
is 0, and E104 error will be displayed. To correct
this, change to a mode that has a fixed field or
modify the mode you are using so the fixed field
is not 0.
Allows you to hear the pitch of the alarm tone.
Allows you to assign Level 1 to the next document fed into
the transport.
Allows you to assign Level 2 to the next document fed into
the transport.
Allows you to assign Level 3 to the next document fed into
the transport.
Allows you to input the next image address. Enter the
next image address, then press Enter.
Allows you to stop the transport.
Allows you to turn on the transport.
Description