Power-Up Reset Timing Diagram - Motorola MC68340 User Manual

Integrated processor with dma
Hide thumbs Also See for MC68340:
Table of Contents

Advertisement

CLKOUT
VCO
LOCK
V CC
RESET
BUS
CYCLES
BUS STATE
UNKNOWN
NOTES:
1. Internal start-up time.
2. SSP read here.
3. PC read here.
4. First instruction fetched here.
Figure 3-28. Power-Up Reset Timing Diagram
When a RESET instruction is executed, the MC68340 drives the RESET signal for 512
clock cycles. The SIM40 registers and the module control registers in each internal
peripheral module (DMA, timers, and serial modules) are not affected. All other peripheral
module registers are reset the same as for a hardware reset. The external devices
connected to the RESET signal are reset at the completion of the RESET instruction.
3-48
Freescale Semiconductor, Inc.
328
512
TCLKIN
TCLKOUT
ADDRESS AND
CONTROL SIGNALS
THREE-STATED
MC68340 USER'S MANUAL
For More Information On This Product,
Go to: www.freescale.com