Cisco Nexus 7000 Hardware Installation And Reference Manual page 450

7000 series
Hide thumbs Also See for Nexus 7000:
Table of Contents

Advertisement

Repacking the System Components
When installing or replacing the unit, the ground connection must always be made first and
Warning
disconnected last. Statement 1046
Disconnect the switch from the console and the network as follows:
Step 5
For each supervisor module, disconnect the cables connected to the console, Com/AUX,
a.
Management, and CMP Management ports.
Note
Disconnect all of the cables from each of the I/O modules.
b.
Disconnect the grounding lug from the front of the chassis as follows:
Step 6
Unscrew the two M4 screws that hold each ground lug to the chassis. For the location of the
a.
grounding pad on the chassis, see
Remove the grounding lug from the chassis and place the two screws in the accessory kit.
b.
If the chassis includes the optional front door and air-intake frame, remove and repack them as follows:
Step 7
Open the door by pulling one of its latch handles out until it clicks (the handle clicks when you pull
a.
it out about 30 degrees) and rotate the door away from the chassis (see
Figure E-5
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
E-12
The CMP feature is available only on Supervisor 1 modules.
Removing One Side of the Front Door
Appendix E
Repacking the Cisco Nexus 7000 Series Switch for Shipment
Figure 3-12 on page
3-22.
Figure
E-5).
OL-23069-07

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 7004Nexus 7009Nexus 7010Nexus 7018

Table of Contents