Chapter 6
Installing Power Supplies
Figure 6-10
Connecting a PIU to a Power Supply and a 3- or 6-kW Power Supply for Input Source Redundancy
1
-
-
+
+
+
+
-
-
1
-
-
+
+
+
+
-
-
-
+
+
1
-
-
+
+
-
1
1
2
3
OL-23069-07
3
- +
- +
2
4
5
6
4
2
4
4
3-kW DC power supply (1 to 4)
Power interface unit (PIU)
Two DC power grids
Connecting a DC Power Supply to DC Power Sources
4
6-kW DC power supply (1 to 4)
5
Connections for 3 kW of available power
6
Connections for 3 kW of reserve power (input
source redundancy)
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
3
- +
- +
2
5
2
6
6-21