Chapter 10
Installing or Replacing Components
Figure 10-43
1
Left door stopper identified with an L on
the bottom of the base.
2
Two M3x14 screws that fasten the stopper
to the left side of the cable management
assembly.
Position the right door stopper (has an R on its base) on the middle of the right side of the cable
Step 3
management frame and fasten it with two M3x14 pan-head screws as shown in
these two screws to 8.4 to 11 in-lb (0.9 to 1.2 N·m).
OL-23069-07
Replacing the Front Door and Air Intake Assemblies on the Cisco Nexus 7018 Chassis
Attaching the Left Door Stopper
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
3
Screw holes on the cable management assembly.
Figure
10-44. Tighten
10-91