Enabling Ports Within A Lag; Monitoring An Individual Lag Port - Dell PowerConnect B-RX Configuration Manual

Bigiron rx series supporting multi-service ironware v02.7.03
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

Use the named option with the appropriate [slot/port] variable to specify a named port within the
LAG that you want to disable.

Enabling ports within a LAG

You can enable an individual port within a trunk using the disable command within the LAG
configuration as shown in the following.
BigIron RX(config)# lag blue static
BigIron RX(config-lag-blue)# deploy
BigIron RX(config-lag-blue)# enable ethernet 3/1
Syntax: [no] enable ethernet [slot/port] | named [name]
Use the ethernet option with the appropriate [slot/port] variable to specify a Ethernet port within
the LAG that you want to enable.
Use the named option with the appropriate [slot/port] variable to specify a named port within the
LAG that you want to enable.

Monitoring an individual LAG port

By default, when you monitor the primary port in a LAG group, aggregated traffic for all the ports in
the LAG is copied to the mirror port. You can configure the device to monitor individual ports in a
LAG including Ethernet, or Named ports. You can monitor the primary port or a secondary port
individually.
NOTE
You can use only one mirror port for each monitored trunk port. To monitor traffic on an individual
port in a trunk group, enter commands such as the following:
This command enables monitoring of an individual port within a LAG.
BigIron RX(config)# lag blue static
BigIron RX(config-lag-blue)# deploy
BigIron RX(config-lag-blue)# monitor ethe-port-monitored 3/1 ethernet 10/3 both
Syntax: [no] monitor ethe-port-monitored [slot/port] | named-port-monitored [name] ethernet
Use the ethe-port-monitored option with the appropriate [slot/port] variable to specify a Ethernet
port within the LAG that you want to monitor.
Use the named-port-monitored option with the appropriate [slot/port] variable to specify a named
port within the LAG that you want monitor.
The ethernet <slot/port> parameter specifies the port to which the traffic analyzer is attached.
The input | output | both parameters specify the traffic direction to be monitored.
NOTE
Mirror (analyzer) ports cannot be assigned to the 16x10G card. You can monitor traffic on 16x10
ports.
BigIron RX Series Configuration Guide
53-1001986-01
[slot/port] [ input | output | both ]