Advertisement

5
Configuring Simple Network Management Protocol traps
You can change the holddown time to a value from one second to ten minutes.
To change the holddown time for SNMP traps, enter a command such as the following at the global
CONFIG level of the CLI.
BigIron RX(config)# snmp-server enable traps holddown-time 30
The command changes the holddown time for SNMP traps to 30 seconds. The device waits 30
seconds to allow convergence in STP and OSPF before sending traps to the SNMP trap receiver.
Syntax: [no]snmp-server enable traps holddown-time <secs>
The <secs> parameter specifies the number of seconds (1 – 600). The default is 60.

Disabling SNMP traps

The device comes with SNMP trap generation enabled by default for all traps.
NOTE
By default, all SNMP traps are enabled at system startup.
You can selectively disable one or more of the following traps:
To stop link down occurrences from being reported, enter the following.
BigIron RX(config)# no snmp-server enable traps link-down
Syntax: [no] snmp-server enable traps <trap-type>
A list of Brocade traps is available in the MIB Reference Guide.
120
SNMP authentication key
Power supply failure
Fan failure
Cold start
Link up
Link down
Bridge new root
Bridge topology change
Locked address violation
Module insert
Module remove
BGP4
OSPF
FSRP
VRRP
VRRPE
BigIron RX Series Configuration Guide