Dell PowerConnect B-RX Configuration Manual page 132

Bigiron rx series supporting multi-service ironware v02.7.03
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

3
System Monitoring Service
NOTE
As a result of the extended monitoring enhancements, any marginal hardware used in previous
releases may be reported as defective.
The shutdown action of the TM register monitor is enabled by default. Enter the following command
to disable this action.
BigIron RX# no sysmon tm reg shutdown
Syntax: [no] sysmon tm reg shutdown
The following table presents the examples of Syslog message generated by SYSMON for the events
that trigger them.
TABLE 34
Syslog messages generated by SYSMON
Syslog message examples
Dec 29 15:31:24:W:System:
ALARM:LP15/TM3 has 6 links, less than
the minimum to maintain line rate
Dec 29 16:25:24:E:System: ALARM:TM
Clock Drift: LP15/TM4 (Reg: 0xbe20,
Value: 0x2b013ffc)
Dec 29 17:19:26:E:System:
ALARM:LP15/TM1 has shutdown (TM
Internal Error: LP15/TM1 (Reg: 0x444,
Value: 0x70000) (shutdown))
Jan 8 11:48:29:E:System:
ALARM:LP3/TM1 has shutdown (TM Q
Stuck: LP3/TM1 (Queue 1024, Size
50331648, Credit 2047, RdPtr 0x0)
(shutdown))]
Jan 8 11:48:19:E:System:
ALARM:LP3/TM1 re-initialized (TM Q
Stuck: LP3/TM1 (Queue 1024, Size
50331648, Credit 2047, RdPtr 0x0) (QDP
reinit))
Jan 8 11:48:19:E:System:
ALARM:LP3/TM1 QDP re-initialized (TM Q
Stuck: LP3/TM1 (Queue 1024, Size
50331648, Credit 2047, RdPtr 0x0) (QDP
reinit))
Dec 31 13:51:42:E:System:
ALARM:LP1/TM1 has shutdown
(LP1/NP1 TCAM failure (shutdown))
Jan 8 08:59:29:E:System:
INFO:LP3/NP2 packet path diagnostic
failure
60
The DRAM CRC detection feature has two methods to detect errors; an interrupt routine is used
to detect these errors quickly then triggers a shutdown of the failed Traffic Manager (TM). Long
term polling detects low rate CRC errors which will be repothe egress port. This process
generates a Syslog message.
Event
Traffic Manager (TM) Link:
TM clock synchronization
TM registers
TM queue scanner
TCAM scan
PKT path scan
Description
Excessive errors on multiple links between
the interface module and the switch fabric
module.
Clock synchronization errors in all TMs of
interface modules.
Errors detected in the TM.
Blocked traffic queues in the TM.
Corruption on the TCAM.
Problems in the packet path from the LP CPU
to the TM to the NP then back to the CPU.