Specify the <dir-path-name> parameter if you want to save the configuration changes to a directory
other than the root directory of a flash card file system.
The <file-name> parameter indicates the name of the saved configuration file.
To change the save location back to flash memory, enter a command such as the following.
BigIron RX# locate startup-config flash-memory switch1.cfg
BigIron RX# write memory

File management messages

The following table lists the messages the CLI can display in response to file management
commands.
TABLE 33
This message...
File not found
Current directory is: <dir-path>
Path not found
There is not enough space on the card
Access is denied
A duplicate file name exists
Fatal error, can not read or write media
There is sharing conflict between
format command and other read/write
operations
Invalid DOS file name
File recovered successfully and named
<file-name>

System Monitoring Service

The System Monitoring Service (SYSMON) feature monitors the hardware in the system to detect,
report, and in some cases isolate and recover hardware errors in the system. When an error or
event occurs, SYSMON generates Syslog messages, which must be reported to Brocade Technical
Support.
SYSMON provides the following:
BigIron RX Series Configuration Guide
53-1001986-01
Flash card file management messages
A read and write test was added to detect failed Switch Fabric Module (SFM) FE failures. A
Syslog message is generated to indicate a SFM FE failure.
System Monitoring Service
Means...
You specified a file name that the software could not find. Verify the
command you entered to make sure the command matches the source
and destination you intended for the file operation.
You have successfully changed the management focus to the slot and
subdirectory indicated by the message.
You specified an invalid path.
The flash card does not have enough space to hold the file you are trying
to copy to it.
You tried to copy or delete a file that has the read-only attribute.
You tried to rename a file using a name that is already in use by another
file.
A hardware error has occurred. One possible cause of this message is if
you removed the flash card while a file operation involving the card was
in progress.
The flash card is currently undergoing formatting. This message also
can show up if you enter a command to format the card while the card is
being accessed for another file operation.
A filename you entered contains an invalid character (for example, ":" or
"\").
A file you tried to recover was successfully recovered under the name
indicated in the message