Front Panel Menu Reference - Agilent Technologies N6705 User Manual

Dc power analyzer
Table of Contents

Advertisement

1 Quick Reference

Front Panel Menu Reference

Menu Heading
Source Settings ►
Voltage and Current Settings...
Protection...
Advanced Protection...
Output On/Off Delays...
Output On/Off Coupling...
Output Grouping...
Advanced...
Ratings...
Arb ►
Arb Preview
Arb Selection...
Meter ►
All Outputs Meter View
Single Output Meter View
Meter Properties...
Scope ►
Standard View
Marker View
Scope Properties...
Marker Properties...
Horizontal Properties...
Datalogger ►
Standard View
Marker View
Datalogger Properties...
File Name Selection...
Marker Properties...
File ►
Save...
Load...
Export...
Import...
Screen Capture...
File Management...
Reset/Recall/Power-On State...
22
Description
Configures the voltage and current settings, ranges, and emulation modes.
Configures the over-voltage and over-current protection. Enables output coupling so ALL
outputs are disabled when a fault occurs. Also clears output protection.
Enables/disables the output inhibit function.
Configures output on/off delays.
Couples specific outputs for the output on/off and delay function.
Groups identical outputs for output paralleling function.
Configures advanced functions including voltage slew rate, sensing, and power limit.
Displays power module ratings, serial number, firmware, and option information.
Displays the present status of the arbitrary waveforms that have been configured.
Selects arbitrary waveforms for each output. Arb Properties configures the selected Arb.
Displays the meter view of all outputs.
Displays the meter view of the selected output.
Configures the meter view voltage and current measurement ranges.
Displays the standard scope view including vertical, horizontal, and trigger settings.
Displays the measurement markers and measurement calculations area.
Configures the scope traces and voltage and current measurement ranges for individual
outputs. Also configures the trigger source, mode, and horizontal offset.
Configures the measurements that appear on the bottom of the display in Marker view.
Configures the horizontal offset reference and sample points.
Displays the data log strip chart view including vertical, horizontal, and progress settings.
Displays the measurement markers and measurement calculations area.
Configures the data log traces and voltage and current measurement ranges for individual
outputs. Also configures the data log duration, sample period, and Min/Max values.
Specifies the filename for the next data logger acquisition.
Configures the measurements that appear on the bottom of the display in Marker view.
Saves an instrument state or a scope measurement.
Loads an instrument state, scope data, or logged data.
Exports scope data, logged data, or a user-defined arbitrary waveform
Imports s user-defined arbitrary waveform.
Captures the screen that was active when the File key was pressed.
Accesses additional file functions: New Folder, Delete, Rename, Copy, File Details.
Resets the instrument to factory defaults; Saves/recalls instrument states; and specifies
the power-on turn on state.
Model N6705 User's Guide