Agilent Technologies N6705 User Manual page 185

Dc power analyzer
Table of Contents

Advertisement

SCPI Command
FETCh[:SCALar] (continued)
:VOLTage
[:DC]? (@chanlist)
:ACDC? (@chanlist)
:HIGH? (@chanlist)
:LOW? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
:ARRay
:CURRent [:DC]? (@chanlist)
:POWer [:DC]? (@chanlist)
:VOLTage [:DC]? (@chanlist)
:DLOG
:AHOur? (@chanlist)
:CURRent
[:DC]? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
:PTPeak? (@chanlist)
:VOLTage
[:DC]? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
:PTPeak? (@chanlist)
:WHOur? (@chanlist)
:ELOG <NR1>, (@chanlist)
:HISTogram
:CURRent? 8 | 0.0039, (@chanlist)
FORMat
[:DATA] ASCII | REAL
:BORDer NORMal | SWAPped
HCOPy:SDUMp:DATA?
INITiate
[:IMMediate]
:ACQuire (@chanlist)
:DLOG <"filename">
:ELOG (@chanlist)
:HISTogram (@chanlist)
:TRANsient (@chanlist)
:CONTinuous
:TRANsient <Bool>, (@chanlist)
MEASure
[:SCALar]
:CURRent
[:DC]? (@chanlist)
:ACDC? (@chanlist)
:HIGH? (@chanlist)
:LOW? (@chanlist)
:MAXimum? (@chanlist)
:MINimum? (@chanlist)
Model N6705 User's Guide
Description
Returns the average voltage
Returns the total rms voltage (AC + DC)
Returns the high level of a voltage pulse
Returns the low level of a voltage pulse
Returns the maximum voltage
Returns the minimum voltage
Returns the instantaneous output current
Returns the instantaneous output power
Returns the instantaneous output voltage
Returns the amp-hours between markers
Returns the average current between markers
Returns the maximum current between markers
Returns the minimum current between markers
Returns the peak-to-peak current between markers
Returns the average voltage between markers
Returns the maximum voltage between markers
Returns the minimum voltage between markers
Returns the peak-to-peak voltage between markers
Returns the watt-hours between markers
Returns the most recent external data log records
Returns the cumulative histogram current data (N6781A, N6782A)
Returns data as ASCII or binary
Sets the byte order of the external data log data
Returns an image of the display in .gif format
Enables measurement triggers
Enables the data logger function
Enables external data logger measurements
Enables histogram measurements (only on N6781A, N6782A)
Enables output triggers
Enables/disables continuous transient triggers
Takes a measurement; returns the average current
Takes a measurement; returns the total rms current (AC + DC)
Takes a measurement; returns the high level of a current pulse
Takes a measurement; returns the low level of a current pulse
Takes a measurement; returns the maximum current
Takes a measurement; returns the minimum current
SCPI Commands Appendix B
185

Advertisement

Table of Contents
loading

Table of Contents