Figure 126 Watch Options Panel
"Contents of the Watch Options Panel" (page 164)
Table 81 Contents of the Watch Options Panel
Item
Copy Group ID
Watch transition to
1
Timeout Hours
Timeout Minutes
SEND Option
1
The sum total of the values specified in Timeout Hours and Timeout Minutes is specified for the TIMEOUT parameter
(timeout value) of the YKWATCH command. If the sum total value exceeds 16,666,666 minutes, execution of the command
results in an error.
NOTE:
In some configurations, such as when BC and CA share volumes or a 1 to n (n is greater
than 2) configuration of BC, the status transitions of each copy pair might not be correctly monitored.

Executing YKEWAIT

If e is specified in the AC column in the Manage Copy Groups panel, the YKEWAIT command will
be executed and the Wait Options panel for specifying the parameters of the YKEWAIT command
is displayed.
Figure 127 (page 165)
164 ISPF Panels
Description
Copy group ID
Specify the waiting status for the YKWATCH command by using the number.
Duplex: Waits for the volume to change to the DUPLEX status.
Suspend: Waits for the volume to change to the SUSPEND status.
Simplex: Waits for the volume to change to the SIMPLEX status.
Specify the value for the TIMEOUT parameter (timeout value) in hour (0 to 999999).
1
Specify the value for the TIMEOUT parameter (timeout value) in minute (0 to 9999).
Specify the USER, OPERATOR, or CN parameter of the YKWATCH command.
and
Figure 128 (page 165)
describes the items in the Watch Options panel.
show the Wait Options panel.