Download Print this page

HP XP P9500 Reference Manual page 53

Hp p9000 for business continuity manager software reference guide
Hide thumbs Also See for XP P9500:

Advertisement

Figure 42 Add Route Entry Panel
In the selection field, specify a relevant value based on the status of the storage system to be added.
How to specify the storage system varies depending on the value specified in the selection field.
The following table describes the values to specify in the selection field and how to specify a
storage system.
Status of the storage
Value to specify in
system
the selection field
A Local Scan or
1
Remote Scan has
already been
performed.
A Remote Scan has
2
not yet been
performed.
If you are using the F5 key in the Route List Information panel to add the first storage system for a
route, 1 is selected and cannot be changed.
Table 31 (page 53)
lists and describes the items in the Add Route Entry panel.
Table 31 Contents of the Add Route Entry Panel
Item
Description
DADID and
DADID
serial
number of
the storage
system
SN
How to specify the storage system to be added (DAD ID and serial number)
If you press the Enter key without specifying values for DADID and SN, a
list of selectable storage systems appears in the Storage System Selection
List panel. Select a storage system from the list.
If you specify a value for DADID or SN, a list of storage systems whose
DAD ID or serial number matches the specified value appears in the
Storage System Selection List panel. Select a storage system from the list.
Directly specify values for DADID and SN.
Specify the DAD ID of the storage system to be
added.
Specify the DAD ID so that the number of characters
in the disk configuration definition file does not
exceed 44 characters when combined with the
value specified for Configuration File Prefix (the
prefix) in the Set Defaults panel.
Specify the serial number of the storage system to
be added.
Discover/Define Configuration Panel (Configuration File Definition)
53

Advertisement

loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1