Download Print this page

HP XP P9500 Reference Manual page 314

Hp p9000 for business continuity manager software reference guide
Hide thumbs Also See for XP P9500:

Advertisement

The following table gives the meanings of the attributes of the Port elements.
Attribute name
PriPort
SecPort
Status
Command Device Container
<!ELEMENT CDEVContainer(CDEVGRP*)>
<!ATTLIST CDEVContainer
DADID
>
The following table gives the meanings of the attributes of the CDEVContainer elements.
Attribute name
DADID
Command Device Group
<!ELEMENT CDEVGRP(CDEV*)>
<!ATTLIST CDEVGRP
DADID
APID
LABEL
CYL
HD
SLOTSIZE
>
The following table gives the meanings of the attributes of the CDEVGRP elements.
Attribute name
DADID
APID
LABEL
CYL
HD
SLOTSIZE
1
XXXX is set for a value whose definition is not yet complete.
Command Device
<!ELEMENT CDEV(DiskDevice)>
<!ATTLIST CDEV
Devn
Volser
DADID
>
314
Data Objects
Meaning
The initiator port number of the primary site of the logical path
The target port number of the secondary site of the logical path
Status of a logical path
ID#REQUIRED
Meaning
DAD ID to which a command device belongs
CDATA#REQUIRED
CDATA#REQUIRED
CDATA#IMPLIED
CDATA#IMPLIED
CDATA#IMPLIED
CDATA#IMPLIED
Meaning
DAD ID to which a command device belongs
1
APID
Route label
First cylinder (fixed value of 0001)
First track (fixed value of 00)
Slot size of dummy dataset (fixed value of 2000)
CDATA#IMPLIED
CDATA#IMPLIED
CDATA#REQUIRED