READY
YKERCODE 6A13
Error details:
The command could not be executed because a remote command was executed
while the command device was not defined.
Type of error:
Others.
Return codes
Table 105 (page 205)
terminates.
Table 105 YKERCODE Command Return Code List
Return Code
0
8
16
64

YKEWAIT Command

Applies to Business Copy for Mainframe, Continuous Access Synchronous for Mainframe, Continuous
Access Synchronous for Mainframe with the HyperSwap attribute, Continuous Access Asynchronous
for Mainframe, and Continuous Access Journal for Mainframe.
Format
YKEWAIT
STEM(stem-name-1)
1
MSG(stem-name-2)
1
GOTO({DUPLEX|SUSPEND|SIMPLEX|SUSPVS|HOLD|SWAPPING})
1
[
TIMEOUT(timeout-value)
1
[
NOINVALIDCHECK]
1
[
DEVN(p-vol-device-number,s-vol-device-number)]
1
[
TO({PRIMARY|SECONDARY})]
1
[
VOLUNIT]
1
Function
This command:
Is a TSO/E command called from REXX scripts.
Monitors the volume status transition of copy pairs for the specified copy group and waits for
a certain specified status.
Works when the storage system has corresponding function.
Parameters
STEM(stem-name- 1 ) ~ <REXX prefix of 64 or fewer characters>
Specify the prefix of the name of the copy group structure that stores information about the copy
group to be monitored. Specify the same character string as the one specified in the STEM parameter
of the YKLOAD command that loaded the corresponding copy group. You must also include a
trailing period character.
lists the return codes that are returned when the YKERCODE command
Meaning
The command completed normally.
No description of the specified error code was found.
Command execution terminated because of an invalid parameter.
The module cannot be loaded. Possible causes are as follows:
The library dataset has not been linked.
The module is protected by the RACF program control function.