Table 142 Host-Discovered Array Structure (continued)
REXX variables
IFType
PhysicalSerialNum
LDKCNum
Key.BC
Key.CA
Key.CAJ
Key.TCA
NGDADIDEnable
CUxx
1
When Business Continuity Manager scans a device that exists in any of the following models, a value of 0 is set:
HP XP12000/XP10000 Disk Array
HP XP24000/XP20000 Disk Array
HP P9500 Disk Array
A value of 0 is also set when the YKLOAD command is executed.
2
Created for each CU, thus the device information is created for each defined CU (CU number). The xx in CUxx is a CU
number (hexadecimal value).
Example of CUxx:
If C400 is set to SSID of CU=05, the value for CU05.SSID is C400.
3
Created for each CCA, thus the device information is created for each defined CCA (CCA number). The xx in CCAxx is
a CCA (hexadecimal value).
Example of CCAxx:
If STRG01 is set to the volume serial number of CCA=FF within CU=05, the value for CU05.CCAFF.Volser is STRG01.
4
When Business Continuity Manager performs a remote scan or an NG scan, information cannot be obtained for the
following models:
XP1024/XP128 Disk Array
XP12000/XP10000 Disk Array
XP24000/XP20000 Disk Array
5
External volume information can be obtained when Business Continuity Manager scans a device that exists in any of the
following storage system models. If information cannot be obtained, the value is null.
HP XP12000/XP10000 Disk Array
HP XP24000/XP20000 Disk Array
P9500 Disk Array
330 Data Objects
1
2
SSID
3
CCAxx
Description
Interface version
Physical DKC serial number
Logical DKC number
BC key
CA key
CAJ key
TCA key
Non Gen'ed function flag
0: Not a Non Gen'ed DAD ID
1: Non Gen'ed DAD ID
One of the storage system IDs of a CU
Device number
Devn
Volume serial number
Volser
Storage system ID
SSID
4
Volume capacity (the number of cylinders)
Cyls
5
External volume information
External
Y: External volume
N: Not an external volume