Return Codes
Table 128 (page 246)
Table 128 YKSTATS Command Return Code List
Return Code
-4095 to -4040
-3
-1
0
32
36
40
44
48
128

YKSTORE Command

Format
YKSTORE
STEM(stem-name-1)
1
PREFIX(prefix)
1
MSG(stem-name-2)
1
[
PATH]
1
[
UIDCHK]
1
Function
YKSTORE command is a REXX subroutine.
This command writes information about the copy group or path set on which an operation is being
performed to the configuration file defined in the ISPF panel. For details about configuration files,
see
"XML Document Type Definitions" (page
Parameters
STEM(stem-name- 1 ) ~ <REXX prefix of 64 or fewer characters>
Specify the prefix of the name of the copy group structure that stores information about the copy
group to be stored in the copy group definition file. Specify the same character string as the one
specified in the STEM parameter of the YKLOAD command that loaded the corresponding copy
group. You must also include a trailing period character.
The copy group structure is initialized for each process.
PREFIX(prefix) ~ <PREFIX string of 25 or fewer characters>
Specify the prefix of the configuration file name.
246 CLI Commands
lists the return codes to be returned when the YKSTATS command terminates.
Meaning
The command terminated abnormally, possibly because the user SVC routine has
not been included properly.
The module cannot be loaded. Possible causes are as follows:
The library dataset has not been linked.
The module is protected by the RACF program control function.
An interruption occurred during execution.
The command completed normally.
I/O errors were encountered.
A change in an I/O configuration definition was detected.
Invalid or missing data in a REXX variable.
An error occurred while a REXX variable was being written.
Terminating due to processing errors.
Terminating due to invalid parameters.
The command terminated abnormally. The user does not have permission to execute
this command.
303).