Download Print this page

HP XP P9500 Reference Manual page 359

Hp p9000 for business continuity manager software reference guide
Hide thumbs Also See for XP P9500:

Advertisement

The messages that are output are as follows:
YK80nnZ: These are messages that are output regardless of the specified message level.
However, note that some messages might be output only to SYSTSPRT or the console.
YK81nnZ: These are messages with the highest level of importance.
YK82nnZ: These are error messages.
YK83nnZ: These are messages that report statuses.
YK84nnZ: These are information messages.
ONACTIONERROR={SKIPONLY|STOP|EXIT(return-code)} ~ <<SKIPONLY>>
Specifies the default error action to be used when no error action is specified in the ACTION
parameter in the YKMONCG file.
SKIPONLY
Skips the cycle where an error occurred, but starts monitoring again from the next cycle.
STOP
Places the monitoring status of all copy groups specified in the CGID parameter to INACTIVE
EXIT(return-code) ~ <numeric characters> ((0 to 4095))
Stops BCM Monitor with the specified return code. HP recommends that you specify a value
other than 0, 4, 8, or 12 because these numbers are already used as BCM Monitor return
codes.
NOTE:
Depending on the configuration of copy groups and the information specified in the
YKMONCG file, the copy group status monitoring cycle might exceed the value specified
in the CYCLETIME parameter.
Even if you choose to omit all the parameters, you still need to create an empty YKMONOPT
file.
You can decrease the amount of log data to be output by specifying CONS for the
SYSTSPRT message level in the MSGLEVEL parameter. However, you might not be able
to identify the cause of an error if a problem occurs.
Example 1
This example has the following operating environment:
Copy group monitoring cycle time: 600 seconds
WAITTIMEOUT value: 60 minutes
Message level output to SYSTSPRT: STATUS
Message level output to the console: CONS
ONACTIONERROR value: STOP
CYCLETIME=600
WAITTIMEOUT=60
MSGLEVEL=STATUS,CONS
ONACTIONERROR=STOP
YKMONOPT File 359

Advertisement

loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1