13.2 Power supply equipment capacity and generated loss

(1) Amount of heat generated by the servo amplifier
Table 12.1 indicates servo amplifier's power supply capacities and losses generated under rated load.
For thermal design of an enclosure, use the values in Table 13.1 in consideration for the worst
operating conditions. The actual amount of generated heat will be intermediate between values at
rated torque and servo-off according to the duty used during operation. When the servo motor is run at
less than the maximum speed, the power supply capacity will be smaller than the value in the table,
but the servo amplifier's generated heat will not change.
Table 13.1 Power supply capacity and generated heat per servo amplifier at rated output
Servo amplifier
Servo motor
HC-KFS053 13
MR-J2S-10CP(1)
HC-MFS053 13
HC-UFS13
HC-KFS23
MR-J2S-20CP(1)
HC-MFS23
HC-UFS23
HC-KFS43
MR-J2S-40CP(1)
HC-MFS43
HC-UFS43
HC-SFS52
MR-J2S-60CP
HC-SFS53
HC-LFS52
HC-KFS73
MR-J2S-70CP
HC-MFS73
HC-UFS72 73
HC-SFS81
MR-J2S-100CP
HC-SFS102 103
HC-LFS102
HC-SFS121
HC-SFS201
HC-SFS152 153
HC-SFS202 203
MR-J2S-200CP
HC-RFS103
HC-RFS153
HC-UFS152
HC-LFS152
HC-SFS301
HC-SFS352 353
MR-J2S-350CP
HC-RFS203
HC-UFS202
HC-LFS202
HC-SFS502
HC-RFS353
HC-RFS503
MR-J2S-500CP
HC-UFS352
HC-UFS502
HC-LFS302
HA-LFS502
HC-SFS702
MR-J2S-700CP
HA-LFS702
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value assumes that the power
factor improving reactor is not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, Refer to section 14.1.1.
(Note 1)
Power supply
Servo amplifier-generated heat[W]
capacity[kVA]
At rated torque
0.3
25
0.3
25
0.3
25
0.5
25
0.5
25
0.5
25
0.9
35
0.9
35
0.9
35
1.0
40
1.0
40
1.0
40
1.3
50
1.3
50
1.3
50
1.5
50
1.7
50
1.7
50
2.1
90
3.5
90
2.5
90
3.5
90
1.8
50
2.5
90
2.5
90
2.5
90
4.8
120
5.5
130
3.5
90
3.5
90
3.5
90
7.5
195
5.5
135
7.5
195
5.5
195
7.5
195
4.5
120
7.5
195
10.0
300
10.6
300
13 - 2
(Note 2)
Area required for heat dissipation
With servo off
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
20
20
20
20
15
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
25
25
[m
]
[ft
]
2
2
0.5
5.4
0.5
5.4
0.5
5.4
0.5
5.4
0.5
5.4
0.5
5.4
0.7
7.5
0.7
7.5
0.7
7.5
0.8
8.6
0.8
8.6
0.8
8.6
1.0
10.8
1.0
10.8
1.0
10.8
1.0
10.8
1.0
10.8
1.0
10.8
1.8
19.4
1.8
19.4
1.8
19.4
1.8
19.4
1.0
10.8
1.8
19.4
1.8
19.4
1.8
19.4
2.7
29.1
2.7
29.1
1.8
19.4
1.8
19.4
1.8
19.4
3.9
42.0
2.7
29.1
3.9
42.0
3.9
42.0
3.9
42.0
2.4
25.8
3.9
42.0
6.0
64.6
6.0
64.6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents