14. OPTIONS AND AUXILIARY EQUIPMENT
b) Control circuit terminal
PC
BUE
SD
A
B
C
Terminal block
(c) Crimping terminals for P and N terminals of servo amplifier
Servo amplifier
MR-J2S-350CP
MR-J2S-500CP
MR-J2S-700CP
POINT
Undertightening can cause a cable disconnection or malfunction.
Overtightening can cause a short circuit or malfunction due to damage to
the screw or the brake unit.
SD
SD SD
RES
MSG
MSG
Jumper
POINT
Always use recommended crimping terminals or equivalent since some
crimping terminals cannot be installed depending on the size.
Brake unit
FR-BU2-15K
FR-BU2-15K
FR-BU2-30K
FR-BU2-30K
Wire the stripped cable after twisting to prevent the cable
from becoming loose. In addition, do not solder it.
Screw size: M3
Tightening torque: 0.5N m to 0.6N m
Cable size: 0.3mm
to 0.75 mm
2
Screw driver: Small flat-blade screwdriver
(Tip thickness: 0.4mm/Tip width 2.5mm)
Number of
connected
Crimping terminal
units
1
1
FVD5.5-S4
1
1
14 - 13
Sheath
Core
6mm
2
Applicable tool
Japan Solderless
YNT-1210S
Manufacturer
Terminal

Hide quick links: