3. SIGNALS AND WIRING
(e) Only main circuit power supply off (control circuit power supply remains on)
Servo motor speed
Base circuit
Electromagnetic
brake interlock (MBR)
Trouble (ALM)
Main circuit
power supply
Note 1. Changes with the operating status.
2. When the main circuit power supply is off in a motor stop status, the main circuit off warning (AL.E9) occurs and the trouble
(ALM) does not turn off.
3. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
(10ms)
(10ms)
Forward
(Note 1)
rotation
15 or more
0r/min
ON
OFF
(Note 3)
ON
OFF
No
(ON)
Yes (OFF)
ON
OFF
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Electromagnetic brake
operation delay time
(Note 2)