5. PARAMETERS
Class No. Symbol
16
*BPS
Serial communication function selection, alarm history clear
Used to select the serial communication baud rate, select various
communication conditions, and clear the alarm history.
17
MOD
Analog monitor output
Used to select the signals to be output to the analog monitor 1 (MO2) and analog
monitor 2 (MO2). (Refer to section 5.2.4)
0
Note. 8V is outputted at the maximum torque. However, when parameter
Name and Function
Serial baud rate selection
(Refer to section 15.2.2)
0: 9600 [bps]
1: 19200[bps]
2: 38400[bps]
3: 57600[bps]
4: 4800[bps] (For MR-DP60)
Alarm history clear (Refer to section 5.2.6)
0: Invalid
1: Valid
When alarm history clear is made valid,
the alarm history is cleared at next power-on.
After the alarm history is cleared, the setting
is automatically made invalid (reset to 0).
Serial communication standard selection
(Refer to section 15.2.2)
0: RS-232C used
1: RS-422 used
Serial communication response delay time
(Refer to section 15.2.2)
0: Invalid
1: Valid, reply sent after delay time of 800 s
or more
0
Setting
Analog monitor 2 (MO2)
0
Servo motor speed ( 8V/max. speed)
1
Torque ( 8V/max. torque) (Note)
2
Servo motor speed ( 8V/max. speed)
3
Torque ( 8V/max. torque) (Note)
4
Current command ( 8V/max. current command)
5
Command pulse frequency ( 10V/500kpulse/s)
6
Droop pulses ( 10V/128 pulses)
7
Droop pulses ( 10V/2048 pulses)
8
Droop pulses ( 10V/8192 pulses)
9
Droop pulses ( 10V/32768 pulses)
A
Droop pulses ( 10V/131072 pulses)
B
Bus voltage ( 8V/400V)
No. 28 29 are set to limit torque, 8V is outputted at the torque highly
limited.
Analog monitor 1 (MO1)
5 - 8
Initial
Setting
Unit
value
range
0000
Refer to
Name
and
function
column.
0100
Refer to
Name
and
function
column.