Mitsubishi Electric MR-J2S-CP Instruction Manual page 147

Melservo j2-super series
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
19
*BLK
Parameter write inhibit
Used to select the reference and write ranges of the parameters.
Operation can be performed for the parameters marked
(initial
value)
(Note)
Note. Set this parameter when making device setting using the MR Configurator
20
*OP2
Function selection 2
Used to select slight vibration suppression control.
0
21
For manufacturer setting
Do not change this value by any means.
22
*OP4
Function selection 4
Used to select stop processing at forward rotation stroke end (LSP), reverse
rotation stroke end (LSN) off.
0
23
SIC
Serial communication time-out selection
Used to choose the time-out period of communication protocol.
Name and Function
Basic
Set
Operation
parameters
value
No.0 to 19
0000
Reference
Write
Reference
No.19 only
000A
Write
No.19 only
Reference
000B
Write
Reference
000C
Write
Reference
000E
Write
(servo configuration software).
0 0
Slight vibration suppression control selection
0: Invalid
1: Valid
0
0
Stopping method used when forward rotation
stroke end (LSP), reverse rotation stroke
end (LSN) device or software limit is valid
(Refer to section 5.2.5)
0: Sudden stop
1: Slow stop
Setting
0
No time-out check
Time-out check period setting
1 to 60
Check period
.
Expansion parameters 2
Expansion
No.54 to 77
parameters 1
special parameters
No.20 to 53
(No. 78 to 90)
Description
setting [s]
5 - 10
Initial
Setting
Unit
value
range
0000
Refer to
Name
and
function
column.
0000
Refer to
Name
and
function
column.
0002
0000
Refer to
Name
and
function
column.
0
0 to 60