Mitsubishi Electric MR-J2S-CP Instruction Manual page 272

Melservo j2-super series
Table of Contents

Advertisement

14. OPTIONS AND AUXILIARY EQUIPMENT
(b) FR-BR resistor unit
14.1.3 Power regeneration converter
When using the power regeneration converter, set "01
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to
the servo amplifiers of the MR-J2S-500CP and MR-J2S-700CP.
Power
regeneration
regenerative
converter
power (kW)
FR-RC15
FR-RC30
2
Control circuit
terminal
Main circuit
terminal
C
Approx. 35
Note. Ventilation ports are provided on both sides and the top. The bottom is open.
Resistor unit
FR-BR-15K
FR-BR-30K
Nominal
Servo amplifier
15
MR-J2S-500CP
MR-J2S-700CP
30
C
(Note)
(Note)
C
Approx. 35
W1
1
W
5
W
W1
H
H1
170
100
450
410
340
270
600
560
" in parameter No.0.
500
300
200
100
50
30
20
0
14 - 15
H2
H3
D
D1
20
432
220
3.2
20
582
220
4
10
50
75
100
Nominal regenerative power (%)
[Unit: mm]
Approximate
C
mass
[kg]([Ib])
6
15(33.1)
30(66.1)
150

Hide quick links: