3. SIGNALS AND WIRING
(6) Source input interface
When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.
For use of internal power supply
(Note)
For a transistor
Approx. 5mA
Switch
TR
V
1.0V
CES
I
100 A
CEO
Note. This also applies to the use of the external power supply.
Since source output is not provided, make the following circuit.
For use of internal power supply
Servo amplifier
24VDC
VDD
COM
ALM, etc
SG
Servo amplifier
SG
R: Approx. 4.7k
COM
SON,
etc.
24VDC
VDD
Load
If the polarity of diode
is not correct, the
servo amplifier will
become faulty.
For use of external power supply
Switch
24VDC
200mA or more
For use of external power supply
Servo amplifier
24VDC
VDD
COM
ALM, etc
SG
Note. If the voltage drop (maximum of 2.6V) interferes with the
relay operation, apply high voltage (up to 26.4V) from
external source.
3 - 24
Servo amplifier
SG
R: Approx. 4.7k
COM
SON,etc.
Do not connect
VDD-COM.
(Note)
24VDC
Load
10%
If the polarity of diode
is not correct, the
servo amplifier will
become faulty.