Mitsubishi Electric MR-J2S-CP Instruction Manual page 153

Melservo j2-super series
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
60
For manufacturer setting
Do not change this value by any means.
61
NH1
Machine resonance suppression filter 1
Used to selection the machine resonance suppression filter.
(Refer to section 9.1.)
0
62
NH2
Machine resonance suppression filter 2
Used to set the machine resonance suppression filter.
0
Name and Function
Notch frequency selection
Set "00" when you have set adaptive vibration
suppression control to be "valid" or "held"
(parameter No. 63:
Setting
Setting
Frequency
Frequency
value
value
00
Invalid
08
562.5
01
4500
09
500
02
2250
0A
450
03
1500
0B
409.1
04
1125
0C
375
05
900
0D
346.2
06
750
0E
321.4
07
642.9
0F
300
Notch depth selection
Setting
Depth
value
0
Deep
1
to
2
Shallow
3
Notch frequency
Same setting as in parameter No. 61
However, you need not set "00" if you have
set adaptive vibration suppression control to
be "valid" or "held".
Notch depth
Same setting as in parameter No. 61
1
or
2
).
Setting
Setting
Frequency
Frequency
value
value
10
281.3
18
187.5
11
264.7
19
180
12
250
1A
173.1
13
236.8
1B
166.7
14
225
1C
160.1
15
214.3
1D
155.2
16
204.5
1E
150
17
195.7
1F
145.2
Gain
40dB
14dB
8dB
4dB
5 - 16
Initial
Setting
Unit
value
range
0000
0000
Refer to
Name
and
function
column.
0000
Refer to
Name
and
function
column.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents