Alter Numerical Values, Parameter Values, Selection Of Alternatives; Alter Numerical Values - Duerkopp Adler 511 Operating Instructions Manual

Cnc automat for bartacking seams and short seams
Table of Contents

Advertisement

8.3
Altering numerical values, parameter values and selection of alternatives
8.3.1

Alter numerical values

18
Call up the technician mode
Turn on the main switch.
The control unit is initialized.
The sewing mode menu appears on the display.
Press the "F" key.
Enter Code 1 (see Chapter 8.5.4).
Press the "OK" key.
The display changes over to the technician mode.
Select the desired line with the "ñ" and "ò" keys.
Press the "OK" key.
The chosen numerical value is marked by a blinking cursor.
Change between the points with the "ï" or "ð" keys.
Increase or reduce the value of the selected point by one with the
"ñ" and "ò" keys.
Press the "OK" key.
The currently set value is applied.
or
Press the "ESC" key.
The original value is maintained.
Note
All values can only be altered within the range of minimum and
maximum values.