8.7

Distributor PCB

Output number
Y1 (FW/FK)
Y2
Y3
Y4 (FS)
Y5
Y6
Y7 - Y12
Y13 (FA)
Y14 - Y17
Y18 - Y19
Y21 - Y23
Y24 - Y28
Y31(X11/ X12: FL)
*: Output is PWM-compatible
78
The distributor PCB is located at the back of the machine below the
clamping foot magnet. All control unit inputs and outputs are
accessible from here. The rear cover must be removed in order to gain
access to the terminals.
Description of the outputs
Output
24V / 4 A
24V / 0.5 A
24V / 3 A
24V / 4 A*
24V / 0.5 A
24V / 0.5 A
24V / 0.5 A
24V / 3 A*
24V / 0.5 A
24V / 6.5 A*
24V / 0.2A
24V / 0.2A
60V / 8A(2A)
Magnets and magnetic valves are connected between +24V (X9) and
the corresponding output (X8, X10).
Assignment
Thread clamp magnet / optional: Thread wiper
magnet
-
-
Thread tension magnet
Optional: Magnetic valve for the "separated
clamping foot 1"
Optional: Magnetic valve for the "separated
clamping foot 2"
-
Thread trimmer magnet
-
-
Optional: Laser marking light 1 – 3
-
Clamping foot magnet