Duerkopp Adler 511 Operating Instructions Manual page 89

Cnc automat for bartacking seams and short seams
Table of Contents

Advertisement

Error code
Description
4312
Unknown dongle type
4530
Menu system / user
-
message error
4537
4900
5101
NV-RAM empty
5104
NV-RAM checksum
error
5804
Free contours:
Checksum incorrect
5808
Error: free seam
contour,
stitch number cannot
be determined
5809
Free contours:
Max. number of partial
contours
5810
Free contours:
Min. number of
stitches per partial
contour
5900
Sequences error –
Invalid sequence
number
6152
Input/output error
-
6154
6204
6351
2
-
I
C error
6354
6551
Upper position error /
6554
AD converter /
6651
Processor error / Step
6751
motor driver
-
6759
7460
Communication test
interface
Possible cause
- Dongle has been
incorrectly formatted
- Dongle faulty
Internal error
Control unit is new, no
data available.
Control unit is from
another machine class,
data is not compatible
- NV-SRAM faulty
- Malfunction
- NV-SRAM faulty
- Malfunction
Internal error
Max. number of partial
contours (intermediate
cuttings) exceeded
Min. number of stitches
per partial contour not
present
Internal error
Internal error
Control unit faulty
Internal error
- Line interference
- Cable to test interface is
faulty
- Internal error
Remedy
- Reformat dongle
- Use a different dongle
Turn machine off and then on again.
Software update.
Inform DA service
Data reset to factory settings
- Check with Multitest.
Check control unit
- Turn machine off and on again.
Data reset to factory settings
- Check with Multitest
- Check control unit
- Switch machine off and on again.
Data reset to factory settings
- Switch machine off and on again
- Software update
- Inform DA Service
Delete the intermediate cutting
operations in the free contours
Change the intermediate cutting
operations in the free contours
- Switch machine off and on again
- Software update
- Inform DA Service
- Switch machine off and on again
- Software update
- Inform DA Service
Check the control unit
- Switch machine off and on again
- Software update
- Inform DA Service
- Switch off source of interference
- Check the cable
- Switch machine off and on again.
1
85

Advertisement

Table of Contents
loading