Error code
Description
3104
24V switching power
supply: overload
3301
Error process –
3320
controller / test
-
process / step motor –
3322
test process /
3330
switch-on process /
-
sewing process /
3332
winding process /
3340
Adjust-help process
3341
3350
-
3351
3353
3360
3361
3400
3401
3403
3358
Sewing procedure:
Handwheel turned
during the interruption
3500
Error Command
-
Interpreter / Motor
3506
synchronization
3520
-
3530
3540
3721
3722
3830
Program Additional
Board: Update error
3840
No response from the
additional board after
the update attempt
4301
Dongle missing
4302
Dongle empty
4304
Wrong dongle type
4307
Wrong machine class
4311
Format-ID error
84
Possible cause
- Overload 24V output
- Short circuit output
distribution board
- Cable connection to the
distribution board
damaged
Internal error
The handwheel has been
turned manually during
sewing interruption
Internal error
- Interference
- Additional Board faulty
- Interference
- Additional Board faulty
No dongle is inserted
No data is saved on the
dongle
The dongle is incorrectly
formatted for the desired
function
Data dongle is not
formatted for Class 511
- Dongle has been
incorrectly formatted
- Dongle faulty
Remedy
- Check the output element or the
other outputs
- Check the connections, fix the
short circuit.
- Check the cable connections
- Switch machine off and on again
- Software update
- Inform DA Service
Cancel the sewing procedure:
Step the pedal backwards
- Switch machine off and on again
- Software update
- Inform DA Service
- Switch machine off and on again
- Replace the control unit
- Switch machine off and on again
- Replace the control unit
- Insert the dongle in the control
unit
- Save data to the dongle
- Use another dongle
- Format a dongle
- Use another dongle
- Format a dongle
- Reformat dongle
- Use a different dongle

Advertisement