Duerkopp Adler 511 Operating Instructions Manual page 56

Cnc automat for bartacking seams and short seams
Table of Contents

Advertisement

52
PWM output test
This testing function checks the function of the magnets.
Start test function with the "OK" key.
Select the desired output element by pressing the "ñ" or "ò" keys.
Switch the selected output element on and off by pressing the "OK"
key.
== PWM output test ==
Output Y31:
The present electricity, flowing through the clamping foot solenoid
will be displayed.
If the machine is equipped with a monitoring switch for the
clamping foot, the Output PWM-1 will have the value + or -,
according to the switching status of the output element.
Press the function key "ESC" in order to leave the testing function.
Caution – Risk of Injury !
Do not reach into the running machine during the functional test of the
output elements.
Output element
Y31
Also refer to the "Distributor PCB" section
0
Function
Clamping foot magnet

Advertisement