Electrical Coherence Fault On The Lever Position (Illuminated = Illuminated Or Flashing); Bargraph 2 Lh Illuminated - Renault Clio Workshop Repair Manual

Automatic transmission
Hide thumbs Also See for Clio:
Table of Contents

Advertisement

Fiches n
24 and 26
Fault finding using bargraph illumination
Ignition off, disconnect the 6 track connector from the computer.
yes
*
And vehicles with load information supplied by the injection computer.
(Without load potentiometer specific to the automatic transmission).
AUTOMATIC TRANSMISSION

BARGRAPH 2 LH ILLUMINATED:

Electrical coherence fault on the lever position
(illuminated = illuminated or flashing).
Is track C on the wiring side isolated from earth?
Ensure the isolation of the line between the starter motor relay
and track C of the automatic transmission computer connector
and that between track C and the injection computer (for
Erase the memory of the automatic transmission computer.
On version E7J*, program the no load and full load positions.
no
Success
Check the multifunction switch on the 6 track connector, computer side
Refer to MR T.A.M., checking the connectors section.
Replace the multifunction switch.
Replace the computer and erase its memory..
On E7J* version, erasing the memory requires the no load and full load
injection versions).
Does the fault reappear?
using a multimeter.
Are the checks correct?
no
values to be reprogrammed.
23-210
23
no
yes
yes
2DMXTT1.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

TraficFuego591119 ... Show all