Bargraph 4 Lh Illuminated: Reception Fault Of The Load Information Provided By The Injection Computer Or Automatic Transmission Load Potentiometer Fau - Renault Clio Workshop Repair Manual

Automatic transmission
Hide thumbs Also See for Clio:
Table of Contents

Advertisement

Fiches n
24 and 26
Fault finding using bargraph illumination
A) Vehicle without automatic transmission potentiometer
- Bargraph 4 illuminated.
Is bargraph 3 also illuminated?
no
Turn the ignition off then on again.
Is the fault confirmed?
yes
Check the injection potentiometer on the injection
side. After repairing on the injection side, erase the
memory of the automatic transmission computer and
program the no load and full load values.
- Bargraph 4 flashing.
Erase the computer memory and program the no
load and full load values.
Check the battery voltage (too low a voltage may
memorise a fault in the starting phase).
Check the condition under the bonnet of the
automatic transmission wiring and also the high
voltage wiring (test with engine running).
AUTOMATIC TRANSMISSION
BARGRAPH 4 LH ILLUMINATED:
of the load information provided by the injection
computer or automatic transmission load
potentiometer fault.
Reception fault
yes
no
Success
23-212
Deal with
bargraph 3 illuminated.
23
2DMXTT1.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

TraficFuego591119 ... Show all